cart details login

New Sales


Introducing NEW Instek GSP-830 Spectrum Analyzer

Superior Performance

  • Frequency Range: 9kHz~3GHz
  • Input Range: -100dBm~+20dBm
  • Average Noise Floor: -117dBm/Hz
  • Power Measurements: ACPR/ OCBW/Channel Power
  • Phase Jitter Measurements
  • Split Window: Simultaneous Measurements in Two Separate Frequency Spans
  • RBW:3KHz, 30KHz, 300KHz, 4MHz
  • 6.4" TFT Color Display, Resolution 640x480
  • Direct VGA output
  • USB/RS232/GPIB (optional) Interface
  • Optional Tracking Generator
  • Optional Preamplifier (GAP-801)

Portability

  • Light Weight at 5.8kg and Compact Size
  • AC/DC/Battery Multi-Mode Power Operation
  • 100 Trace/State Memories with Date/Time stamp and file name

Easy-To-Use

  • Autoset Function
  • 5 Markers: Delta Mode, Peak Functions, 10 Markers with All Peaks Function
  • Trace Function: Dual-Trace Display, Peak Hold, Freeze, Average, Trace Math
  • Limit Line: Upper/Lower Limit with Pass/Fail Test
  • Trigger Function: Video/ External
  • Clock/Calendar: Time/Date Stamp in Saved Data
  • Wide Range of External Reference Clock: 1MHz…19.2MHz

Pricing Information (Click for Internet Special)

GSP-830: $5990.00

Factory Installed Options:

Accessories:

Wide Measurement Range
With GW Instek state-of-the-art design, GSP-830's outstanding noise floor level, -152dBm/Hz @600MHz, presents
extreme sensitivity for picking up weak signals.
Along with GAP-810 10dB-gain preamplifier, GSP-830 reaches the equivalent noise floor level as low as 162dBm/Hz,
thus widely extend the measurement range.

Automatic Measurement
GSP-830 can be an automatic test instrument without any external computer control.
Users can define their own macros through a keypad on the front panel and store them into 10 Sequence sets.
The sequence includes the steps of pause, so the running sequence could be stopped for measurement result observation,
then continue when necessary.
Repeat or Single run modes can be selected based on the application requirements.

Portable Power Operations
Equipped with two packs of Li-ion battery, GSP-830 could maintain its normal operation for more than 3 hours.
The DC operation mode also allows GSP-830 to be powered by a 12-Volt power supply or the power of cigar-lighter inside the automobile.
The large-size internal memory of GSP-830 helps store measured traces, setup information, limit lines and user-defined macros.
Along with the USB feature to adopt the popular flash drive for mass storage, GSP-830 is a convenient tool for the service engineers.
With only 6kg light weight and compact size, GSP-830 well fits into outdoor applications.

Advanced User Interface
The user-oriented interface design of GSP-830 gives you the pleasure of handling a complicated job with ease.
A high- resolution 6.4" color TFT LCD provides high quality image display.
Multiple traces with different colors, as defined by the user, facilitate the visual recognition of small disparities at a glance.
Split window mode delivers the value for monitoring two different frequency bands on the same display at the same time.
GSP-830 under this split-window mode acts like a product of two-spectrum-analyzers-in-one.

Feature-Rich Interface
The front panel USB host connector supports the ubiquitous flash drive for various transactions, including setup info,
trace data and display images.
In addition, it also supports the direct screen printout for the printers with USB ports.
The rear panel USB On-The-Go, or OTG, connector plays the dual roles of both host and slave.
As a slave, it gives accessibility to the remote control from PC.
The display image of GSP-830 could be sent directly to the external monitors through a VGA port on the rear panel.
This gives convenience for the remote monitoring at EMI test sites or the circumstances needing presentation or group discussion.

Free PC Software for GSP-830/GSP-827
Through RS-232 or USB connection, EagleShot transfers the measurement data from GSP-830 to the PC.
Users can print out the data in graphical format directly or save them into text file for further data analysis.
With EagleShot software, the Limit Line setting on the PC could be done either through capturing the setting from GSP-830
or through the Limit Line editing by the user at the PC end.
For marking and reading the measured signals on the PC screen, users can place markers to the peaks of their interest on the display,
as easily as they do on GSP-830.
The new EagleShot PC software supports both GSP-830 and GSP-827 in various application fields.

 

GSP-830 3.0 GHz. Spectrum Analyzer Specifications

 

FREQUENCY

Frequency Range

9kHz ~ 3GHz

 

Aging Rate

 10ppm, 0-50  C, 5ppm/yr

 

 Span Range

2kHz ~ 3GHz in 1-2-5 sequence, full span, zero span

 

 Phase Noise

-80dBc/Hz @1GHz  , 20kHz offset typical

 

Sweep Time Range

50ms ~ 25.6s

RESOLUTION BANDWIDTH

RBW Range

 

 

RBW Accuracy

3kHz, 30kHz, 300kHz, 4MHz

 

Video Bandwidth Range

15%

AMPLITUDE

Measurement Range

10Hz ~ 1MHz in 1-3 steps

 

 

-103dBm ~ +20dBm, 1MHz ~ 15MHz , Ref. Level   -30dBm

 

 

-120 +/-  1dBm~+20dBm, 15MHz ~600MHz, Ref. Level@-50dBm

 

 

-117  +/- 1dBm~+20dBm, 600MHz~2.3GHz, Ref. Level@-50dBm

 

 

-115  +/- 1dBm~+20dBm, 2.3GHz ~ 3GHz

 

Overload Protection

+30dBm, 25VDC

 

Reference Level Range

-110dBm ~ +20dBm

 

Accuracy

1dB @100MHz

 

Frequency Flatness

1dB

 

Display Range Linearity

1dB over 70dB

 

 

 

DYNAMIC RANGE

 Average Noise Floor

-135dBm/Hz, 1MHz ~ 15MHz , Ref. Level   -30dBm

 

 

-152 +/- 1dBm/Hz, 15MHz ~ 600MHz, Ref. Level@-50dBm

 

 

-149 +/- 1dBm/Hz, 600MHz ~ 2.3GHz, Ref. Level@-50dBm

 

 

-147  +/- 1dBm/Hz, 2.3GHz ~ 3GHz

 

Third Inter-Modulation

< -70dBc @-40dBm Input , Ref. Level@-30dBm

 

 Harmonic Distortion

< -60dBc RF Input < -40dBm, Ref. Level@-30dBm

 

 Non-Harmonic Spurious

< -110dBm @3kHz RBW

GENERAL

Display

640 x 480 high resolution Color  TFT LCD

 

Internal Memory

10 Traces , 10 Setup info , 10 Limit lines , 5 Corrections , 10 Sequences

 

Markers

10 Markers for peaks; 5normal-delta marker pairs ;

 

Trace Detection

 Functions: Delta , Peak , Marker Track

 

 Power Measurement

3 traces with Peak, Maximum hold, Freeze, Average and Trace math

 

 Autoset Function

ACPR, OCBW, Channel power, N dB  BW, and Phase jitter

 

 Sequence

Auto tuning the measurement result for observation

CONNECTORS

RF-Input

Automated test by user-defined macros without any remote control

 

External Reference

Type: N female, 50      nominal ; RF input VSWR: <2 : 1 @ 0dBm Ref. Level

 

Clock Input

Jack: 5.5mm, 12V Sub-D 9 pins female

 

External Trigger Input

1M, 1.544M, 2.048M, 5M, 10M, 10.24M, 13M, 15.36M, 15.4M, 19.2M

 

 Reference Clock Output

Type: BNC female, accept +5-V TTL signal

 

 DC Input

Type: BNC female, 10MHz

 

RS-232C

Jack: 5.5mm, 12V

 

USB Connector

Sub-D 9 pins female

 

DC Voltage Output Terminal

Front panel: type A receptacle ; Rear panel: type mini-B receptacle

POWER SOURCE

AC 100 ~ 240V, 50/60Hz

Type: SMB male, outputs +9V/100mA max.

ACCESSORIES

Power cord x 1 , User manual x 1

 

 DIMENSIONS & WEIGHT

330(W) x 170(H) x 340(D) mm, Approx. 6kg

 

 

 

 

  

OPTION LIST

 

 

Option 01 Tracking Generator

 

 

 

Frequency Range:

 9kHz ~ 3GHz

 

Amplitude Range:

 -50dBm ~ 0dBm

 

Amplitude Accuracy:

 1dB@100MHz, 0dBm

 

Amplitude Flatness:

 1dB@0dBm

 

Harmonics:

 <-30dBc typical

 

Reverse Power

: +30dBm

 

Type:

 N female, 50      nominal

 

TG Output VSWR:

<2:1

Option 02    Battery Pack

 

10.8V Li-Ion battery pack x 2

Opt. 03       1ppm Stability

 

1ppm , 0 ~ 50  C,    1ppm/yr

Opt. 04       300Hz RBW

 

 RBW 300Hz, 3dB bandwidth

 

 

RBW accuracy : 20%

Opt. 05     9kHz & 120kHz RBW(*)

 

RBW selections : 9kHz and 120kHz, 6dB bandwidth

 

 

RBW accuracy : 15%

Opt. 06    10kHz & 100kHz RBW(*)

RBW selections : 10kHz and 100kHz, 3dB bandwidth

 

 

RBW accuracy : 15%

Opt. 07    AM/FM Demodulator

 

Demodulation : AM , FM

       & 10kHz & 100kHz RBW(*)

 

Output : internal speaker, 3.5mm stereo jack wired for mono operation

 

 

RBW selections : 10kHz and 100kHz, 3dB bandwidth

 

 

RBW accuracy : 15%

Opt. 08    GPIB Interface

 

IEEE 488 bus

OPTIONAL ACCESSORY

 

 

GSC-001 

Soft Carrying Case

 

GKT-001 

General Kit set

ADP-002: adaptor, SMA(J/F) ~ N(P/M)  x 2

 

 

ATN-100: 10dB attenuator, N(J) ~ N(P) x 1

 

 

GTL-303: RF cable assembly(SMA(P),RD316,600mm)x2

 

 

GSC-002: Kit box x 1

GKT-002 

CATV Kit set

ADP-001: adaptor, BNC(J/F) ~ N(P/M)  x 2

 

 

ADP-101:  adaptor,BNC(J/F)75     ~BNC(P/M)50      x 2

 

 

GTL-304: RF cable assembly(RG223,N(P)-N(J),300mm)x2

 

 

GSC-003: Kit box x 1

GKT-003

 RLB Kit set

GAK-001: termination 50     , N(P) x 1

 

 

GAK-002: Cap with chain, N(P) x 1

 

 

GTL-302: RF cable assembly(RG223,N(P),300mm)x2

 

 

GSC-004: Kit box x 1

GTL-401

 DC Power Cord

DC power cord with DC Jack and lighter plug,Current 5A

GAP-801 

Pre-Amplifier

 GAP-801: Pre-amplifier with 10dB(typical) 9kHz ~ 6GHz

 

 

 

NOTE : 1. (*) Only one option can be selected among Opt. 05 to 07.     

2. Opt. 01 & 03 to 07 are factory-installed.

 

 

 

 

 

 

ORDERING INFORMATION

STANDARD ACCESSORIES

OPTIONS

GSP-830 3GHz Spectrum Analyzer

User Manual , Power Cord

Please see SPECIFICATIONS

Copyright © Exphil 2008 Privacy Policy